Open Loop Hall Current Sensor/Transducer Simple Introduction
1. Hall effect open loop current sensor/transducers:

 

a. Primary current Ip applied on core    causing Hall Voltage rise, which is due  to the magnetic induction generated on  core.
b. Ic is a constant current source to supply  Hall Senor, which make it under constant  operation condition.
c. Output voltage Vo then is proportion to  Ip which means it get a very good    linearity before core and OP saturation.


2. Characteristics and feature:


a. Measurable current range:
  about 3 times of rated current.
b. Output signal:
  It is directly proportional to the measured current, both DC/AC measurable. General Voltage  output Vo is 4V at the rated (nominal) current Irate. Different Vo versions are also available.
c. Measurement accuracy:
 Depends on ambient temperature, operating temperature and some other electrical parameters.  Our current sensors are Factory-calibrated(offset and gain voltage) at an ambient temperature of 25℃

3. Criteria dynamic behavior:
a. Response time:

★. definition:
 the delay time between 90% of measurable  current range(3 times of rated current) and  sensor output reach the coordinated Voltage


★.specification:
 BesTeks open loop current sensors have the  Best performance Through our best design  of layout and well selection of high slew   Rate amplifier.

b. Noise response:

★ Voltage Pulse applied 300~600V/us on    primary conductor.

★ with control power supply on.

★ measure output voltage(Vo),specification is   depended on the application situation.    However the smaller , the better.

★ BesTeks open loop current sensors have    the excellent low output voltage(Vo)    while compared to others.

c. Output voltage(Vo) linearity:

★ ideal current sensor (without setting error in  residual and output voltage) the output   voltage versus input current relation     indicates the dot line in left figure

★ Actual sensors show the continue line in   the figure.

4. Output voltage(Vo) performance(sample: Rated current 50A) :

★ offset standard specification:
  ± 40mV

★ Output voltage(Vo) standard   specification:±4±0.04V

 